Pump stuck or running dry

Gas boiler
Free account: 1 more check, the readings and the manual page (page 67). No card needed.See the full 281 answer

What it means

The boiler has detected that the pump is stuck or running dry.

Likely causes

  1. Pump seized.
  2. System not vented.
  3. Low operating pressure.
  4. Faulty low pressure switch.
  5. Poor pump connections.

Where to start

  1. Vent the system.
  2. Check the operating pressure.
  3. Check the low pressure switch.

The full answer, free

  • 1 more check in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 67), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.