Worcester Bosch Greenstar 2000 fault 232
Heat source locked by external switching contact
Gas boilerFree account: 10 more checks and the manual page (page 66). No card needed.See the full 232 answer
What it means
Heat source locked by external switching contact. Category B (blocking fault).
Likely causes
- External switching contact plug not connected
- Condensate pump jumper not installed
- External temperature switch switching point mismatch
- Faulty connecting lead to external temperature switch
- Dry run - pump operating without water
- Overload of motor due to friction, particles, impeller blocked with debris or too high viscosity
- Generator operation - pump rotor driven by external flow
- Under or over voltage - mains supply U<160V or U>280V
- Over speed - pump rotor driven by external flow above maximum allowed value
- Over current - abnormal current exceeding limit
- Module over temperature - temperature inside motor too high
- Turbine mode - pump driven by external flow >1200l/h in opposite direction
- Faulty electronic module and/or faulty motor
- Pump not connected to mains supply
- Faulty LED
- Alternative pump setting entered inadvertently, affecting hot water performance
Where to start
- Check plug connection for external switching contact
- Check condensate pump jumper installation per manufacturer spec
- Check switching point of external temperature switch
The full answer, free
- 10 more checks in order
- How to put it right, step by step
- The manual page for this fault (page 66), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
Full 232 fix, readings and manual page. Free.See the full answer
From the Worcester Bosch manual for the Greenstar 2000. Check the model on the data plate before you order parts.
Other Worcester Bosch Greenstar 2000 fault codes
- 1013Maximum combustion point reached
- 1021DHW temperature sensor faulty
- 1065Pressure sensor faulty or not connected
- 1073Flow temperature sensor short circuit
- 1074No signal from the flow temperature sensor
- 1075Short circuit in heat exchanger temperature limiter
- 214Fan stops during safety time
- 215Fan too fast
- 224Flue gas or heat exchanger temperature limiter tripped
- 227No flame detected
- 228Flame signal present although burner switched off
- 233Fault in code plug or appliance electronics
- 234Electrical fault in gas valve
- 237System fault
- 242System fault, appliance electronics
- 244System fault, appliance electronics / basic controller
- 264Air feed failed during operating phase
- 269Flame monitoring
- 281Pump stuck or running dry
- 2910Fault in flue system
- 2917No flame signal when checking the combustion control
- 2925System fault, appliance electronics
- 2926System fault, appliance electronics
- 2927No flame detected during ignition