Worcester Bosch Greenstar 2000 fault 1065

Pressure sensor faulty or not connected

Gas boiler
Free account: the readings and the manual page (page 68). No card needed.See the full 1065 answer

What it means

Pressure sensor faulty or not connected.

Likely causes

  1. Disconnected plug
  2. Faulty pressure sensor
  3. Broken or short-circuited connecting lead
  4. Faulty appliance electronics

Where to start

  1. Check plug, connect correctly
  2. Check pressure sensor
  3. Check connecting lead for breaks or short circuits

The full answer, free

  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 68), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

Full 1065 fix, readings and manual page. Free.See the full answer

From the Worcester Bosch manual for the Greenstar 2000. Check the model on the data plate before you order parts.

Other Worcester Bosch Greenstar 2000 fault codes