Worcester Bosch Greenstar 2000 fault 2910

Fault in flue system

Gas boiler
Free account: 15 more checks, the readings and the manual page (page 69). No card needed.See the full 2910 answer

What it means

Fault detected relating to the flue system.

Likely causes

  1. Flue system not connected
  2. Obstruction in flue system cross-section
  3. Faulty seals around burner, internal flue, or case seals causing air dilution/leakage
  4. Flue system integrity fault
  5. Combustion circuit fault

Where to start

  1. Check whether a flue system is connected
  2. Check for unobstructed cross-section of flue system
  3. Set boiler to maximum rate

The full answer, free

  • 15 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 69), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

Full 2910 fix, readings and manual page. Free.See the full answer

From the Worcester Bosch manual for the Greenstar 2000. Check the model on the data plate before you order parts.