Worcester Bosch Greenstar 2000 fault 342

Temperature increase in DHW mode too rapid

Gas boiler
Free account: 9 more checks, the readings and the manual page (page 67). No card needed.See the full 342 answer

What it means

Temperature increase in DHW mode too rapid.

Likely causes

  1. Water pressure too low
  2. Service valves in cylinder charging circuit closed
  3. Faulty diverter valve / cylinder primary pump
  4. Dry run - pump operating without water
  5. Overload of motor due to friction, particles, impeller blocked with debris or too high viscosity
  6. Generator operation - pump rotor driven by external flow
  7. Under or over voltage - mains supply U<160V or U>280V
  8. Over speed - pump rotor driven by external flow above maximum allowed value
  9. Over current - abnormal current exceeding limit
  10. Module over temperature - temperature inside motor too high
  11. Turbine mode - pump driven by external flow >1200l/h in opposite direction
  12. Faulty electronic module and/or faulty motor
  13. Pump not connected to mains supply
  14. Faulty LED
  15. Alternative pump setting entered inadvertently, affecting hot water performance

Where to start

  1. Check water pressure, top up and vent if low
  2. Open service valves in the cylinder charging circuit
  3. Observe LED colour and pattern on pump operation/fault indicator.

The full answer, free

  • 9 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 67), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

Full 342 fix, readings and manual page. Free.See the full answer

From the Worcester Bosch manual for the Greenstar 2000. Check the model on the data plate before you order parts.