Worcester Bosch Greenstar 2000 fault 341

Heat source temperature increase too rapid

Gas boiler
Free account: 10 more checks, the readings and the manual page (page 67). No card needed.See the full 341 answer

What it means

Heat source temperature increase too rapid.

Likely causes

  1. Isolation valves closed
  2. Pump plug not connected
  3. Faulty pump
  4. Circulating pump not set to Constant speed mode curve III
  5. Dry run - pump operating without water
  6. Overload of motor due to friction, particles, impeller blocked with debris or too high viscosity
  7. Generator operation - pump rotor driven by external flow
  8. Under or over voltage - mains supply U<160V or U>280V
  9. Over speed - pump rotor driven by external flow above maximum allowed value
  10. Over current - abnormal current exceeding limit
  11. Module over temperature - temperature inside motor too high
  12. Turbine mode - pump driven by external flow >1200l/h in opposite direction
  13. Faulty electronic module and/or faulty motor
  14. Pump not connected to mains supply
  15. Faulty LED
  16. Alternative pump setting entered inadvertently, affecting hot water performance

Where to start

  1. Open isolation valves
  2. Connect plug to pump
  3. Ensure circulating pump is set on Constant speed mode - curve III

The full answer, free

  • 10 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 67), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

Full 341 fix, readings and manual page. Free.See the full answer