Worcester Bosch Greenstar 2000 fault 2967

Temperature differential between flow sensor and heat exchanger limiter too great

Gas boiler
Free account: 4 more checks, the readings and the manual page (page 71). No card needed.See the full 2967 answer

What it means

Temperature differential between flow temperature sensor and heat exchanger temperature limiter is too great.

Likely causes

  1. Low flow
  2. System not filled
  3. Air locks
  4. Faulty isolation valves
  5. Pump fault
  6. Sensor contact issues
  7. Faulty stat resistance
  8. Harness fault

Where to start

  1. Check flow through appliance and system filled.
  2. Check for air locks in the system. Purge if required.
  3. Check isolation valves.

The full answer, free

  • 4 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 71), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

Full 2967 fix, readings and manual page. Free.See the full answer

From the Worcester Bosch manual for the Greenstar 2000. Check the model on the data plate before you order parts.