Worcester Bosch Greenstar 2000 fault 2961
No signal from fan
Gas boilerFree account: 2 more checks, the readings and the manual page (page 71). No card needed.See the full 2961 answer
What it means
The boiler is getting no signal from the fan. The manual prints the same entry for 2961 and 2962.
Likely causes
- Fan not receiving mains voltage.
- Fan harness fault.
- PWM (pulse width modulation) signal fault.
- Faulty fan.
- Faulty PCB.
Where to start
- Check the mains voltage to the fan.
- Check the fan harness for continuity.
- Check the pulse width modulation (PWM) signal.
The full answer, free
- 2 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 71), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
Full 2961 fix, readings and manual page. Free.See the full answer
From the Worcester Bosch manual for the Greenstar 2000. Check the model on the data plate before you order parts.
Other Worcester Bosch Greenstar 2000 fault codes
- 1013Maximum combustion point reached
- 1021DHW temperature sensor faulty
- 1065Pressure sensor faulty or not connected
- 1073Flow temperature sensor short circuit
- 1074No signal from the flow temperature sensor
- 1075Short circuit in heat exchanger temperature limiter
- 214Fan stops during safety time
- 215Fan too fast
- 224Flue gas or heat exchanger temperature limiter tripped
- 227No flame detected
- 228Flame signal present although burner switched off
- 232Heat source locked by external switching contact
- 233Fault in code plug or appliance electronics
- 234Electrical fault in gas valve
- 237System fault
- 242System fault, appliance electronics
- 244System fault, appliance electronics / basic controller
- 264Air feed failed during operating phase
- 269Flame monitoring
- 281Pump stuck or running dry
- 2910Fault in flue system
- 2917No flame signal when checking the combustion control
- 2925System fault, appliance electronics
- 2926System fault, appliance electronics