Worcester Bosch Greenstar 2000 fault 2954
No flame signal with high output
Gas boilerFree account: 33 more checks, the readings and the manual page (page 71). No card needed.See the full 2954 answer
What it means
No flame signal with high output. Burner restarts automatically after purging.
Likely causes
- Worn burner gaskets
- Excessive burner load
- Incorrect CO2 settings
- Flue issues
- Incorrect gas type
- Incorrect gas supply pressure
- Flue system blockage or damage
- Incorrect gas/air ratio
- Faulty ratio control valve
- Condensate drain blocked
- Incorrect fan depression
- Incorrect pump rate or pump characteristic map setting
- Unbalanced system
- Incorrect anti-cycle time
- Faulty ignition transformer
- Faulty electrodes
- Faulty burner
- Faulty non-return valve in air/gas manifold
- Faulty turbine
- Faulty diverter valve
- Cross-piping
- Faulty plate heat exchanger
- Faulty flow device
- Faulty silencer body
- Damaged electrical wiring
- Blown fuse
Where to start
- Check and replace burner gaskets.
- Reduce burner load.
- If the fault occurs repeatedly, check the settings of the CO2 values.
The full answer, free
- 33 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 71), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
Full 2954 fix, readings and manual page. Free.See the full answer
From the Worcester Bosch manual for the Greenstar 2000. Check the model on the data plate before you order parts.
Other Worcester Bosch Greenstar 2000 fault codes
- 1013Maximum combustion point reached
- 1021DHW temperature sensor faulty
- 1065Pressure sensor faulty or not connected
- 1073Flow temperature sensor short circuit
- 1074No signal from the flow temperature sensor
- 1075Short circuit in heat exchanger temperature limiter
- 214Fan stops during safety time
- 215Fan too fast
- 224Flue gas or heat exchanger temperature limiter tripped
- 227No flame detected
- 228Flame signal present although burner switched off
- 232Heat source locked by external switching contact
- 233Fault in code plug or appliance electronics
- 234Electrical fault in gas valve
- 237System fault
- 242System fault, appliance electronics
- 244System fault, appliance electronics / basic controller
- 264Air feed failed during operating phase
- 269Flame monitoring
- 281Pump stuck or running dry
- 2910Fault in flue system
- 2917No flame signal when checking the combustion control
- 2925System fault, appliance electronics
- 2926System fault, appliance electronics