Worcester Bosch Greenstar 2000 fault 2950

No flame signal following starting procedure

Gas boiler
Free account: the readings and the manual page (page 70). No card needed.See the full 2950 answer

What it means

No flame signal after the start sequence finished. The burner restarts automatically after purging.

Likely causes

  1. Incorrect CO2 settings.
  2. Faulty burner or heat exchanger gaskets.
  3. Incorrect gas pressure at full load.

Where to start

  1. Check the CO2 settings and adjust if necessary.
  2. Check the burner and heat exchanger gaskets.
  3. Check the gas pressure while burning at full load.

The full answer, free

  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 70), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

Full 2950 fix, readings and manual page. Free.See the full answer

From the Worcester Bosch manual for the Greenstar 2000. Check the model on the data plate before you order parts.

Other Worcester Bosch Greenstar 2000 fault codes