Midea R32 M thermal Arctic Mono fault P5
High temperature difference between water side heat exchanger water inlet and water...
Heat pumpWhat it means
Error code 25. Protection triggered by high temperature difference between water side heat exchanger inlet and outlet temperatures, detected by user interface and hydronic system main PCB.
Likely causes
- Water piping contains air
- Insufficient water flow rate in cooling mode
- Low water flow rate
- Pump fault
- Insufficient refrigerant caused by refrigerant leakage
- Low pressure side blocked by crushed or bent pipe, blocked EXV, or dirty filter
- Poor air side heat exchanger heat exchange in heating or DHW mode
Where to start
- Repair or replace crushed/bent water piping
- Adjust pump speed setting
- Perform air purging procedure on water system
The full answer, free
- 30 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 67), right under the answer
Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.
From the Midea manual for the R32 M thermal Arctic Mono. Check the model on the data plate before you order parts.
Other Midea R32 M thermal Arctic Mono fault codes
- BHPED board checking fail
- C7Transducer module temperature too high protect
- D0Oil return operation in progress
- E0Water flow failure (repeated E8 occurrence)
- E1Phase sequence error
- E2Communication error between outdoor unit and user interface
- E3Backup electric heater water outlet temperature sensor error
- E4Domestic hot water tank temperature sensor error
- E5Air side heat exchanger refrigerant outlet temperature sensor error
- E6Outdoor ambient temperature sensor error
- E7Balance tank sensor Tbt1 error
- E8Water flow failure
- E9Suction pipe temperature sensor error
- EADischarge pipe temperature sensor error
- EBSolar board sensor tsolar error
- ECBalance tank sensor Tbt2 error
- EDWater side heat exchanger water inlet temperature sensor error
- EEHydronic system EEPROM error
- ELCommunication fault between hydraulic module and MH-kit
- F1DC bus voltage is too low
- H0Communication error between refrigerant system main control chip and hydronic system...
- H1Communication error between refrigerant system main control chip and inverter driver chip
- H2Water side heat exchanger refrigerant inlet (liquid pipe) temperature sensor error
- H3Water side heat exchanger refrigerant outlet temperature sensor error