Midea R32 M thermal Arctic Mono fault E2
Communication error between outdoor unit and user interface
Heat pumpWhat it means
Communication error between outdoor unit and user interface. M thermal Mono stops running. Error code is displayed on hydronic system main control board for refrigerant system and user interface.
Likely causes
- Loose wiring
- Damaged PCB or terminals
- Communication wires not connected in daisy chain topology
- Damaged main PCB or electric control box communication terminals block
- Loose wire connections at communication terminals block
- Short circuit, disconnection, or misconnection of communication wires
- Communication wires between outdoor unit and user interface not connected properly
- Communication wiring X Y E terminals misconnected
- Loosened wiring within electric control box
- Short circuit in communication wires, disconnected wires, or incorrect wire connections
- Loose communication wiring, damaged communication cable, PCB malfunction, shielding issue
- Wires not fully inserted into connectors
- Hydronic box main PCB fault
- Damaged cables between hydronic box main PCB and outdoor unit main PCB
- Outdoor unit main PCB fault
- Incorrect or abnormal input power supply (N or L)
Where to start
- Step 1: Check communication wire connections between outdoor unit and user interface
- Step 3: Inspect electric control box for loosened wiring
- Step 5: Inspect main PCB and communication terminals for damage or blockage
The full answer, free
- 24 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 73), right under the answer
Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.
From the Midea manual for the R32 M thermal Arctic Mono. Check the model on the data plate before you order parts.
Other Midea R32 M thermal Arctic Mono fault codes
- BHPED board checking fail
- C7Transducer module temperature too high protect
- D0Oil return operation in progress
- E0Water flow failure (repeated E8 occurrence)
- E1Phase sequence error
- E3Backup electric heater water outlet temperature sensor error
- E4Domestic hot water tank temperature sensor error
- E5Air side heat exchanger refrigerant outlet temperature sensor error
- E6Outdoor ambient temperature sensor error
- E7Balance tank sensor Tbt1 error
- E8Water flow failure
- E9Suction pipe temperature sensor error
- EADischarge pipe temperature sensor error
- EBSolar board sensor tsolar error
- ECBalance tank sensor Tbt2 error
- EDWater side heat exchanger water inlet temperature sensor error
- EEHydronic system EEPROM error
- ELCommunication fault between hydraulic module and MH-kit
- F1DC bus voltage is too low
- H0Communication error between refrigerant system main control chip and hydronic system...
- H1Communication error between refrigerant system main control chip and inverter driver chip
- H2Water side heat exchanger refrigerant inlet (liquid pipe) temperature sensor error
- H3Water side heat exchanger refrigerant outlet temperature sensor error
- H5Room temperature sensor error