Midea R32 M thermal Arctic Mono fault H0

Communication error between refrigerant system main control chip and hydronic system...

Heat pump

What it means

Communication error between refrigerant system main control chip and hydronic system main control chip (serial number 39). Displayed on user interface, refrigerant system main control board for refrigerant system and hydronic system main PCB.

Likely causes

  1. Communication wiring/link fault between refrigerant and hydronic control chips
  2. Loose inter-PCB wiring, damaged communication cable, PCB malfunction, shielding issue
  3. Power supply abnormal. Transformer malfunction. Interference from a source of electromagnetic radiation. Refrigerant system main PCB or hydronic system main PCB damaged.
  4. Hydronic box main PCB fault
  5. Damaged cables between hydronic box main PCB and outdoor unit main PCB
  6. Outdoor unit main PCB fault
  7. Incorrect or abnormal input power supply (N or L)
  8. Wires not fully inserted into connectors

Where to start

  1. Inspect inter-PCB wiring connections, verify cable integrity, check for EMI interference, test PCB communication
  2. Check power supply status. Check transformer operation. Assess electromagnetic interference sources. Inspect refrigerant system main PCB and hydronic system main PCB for damage.
  3. Follow flowchart sequence starting at H0

The full answer, free

  • 10 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 66), right under the answer

Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.

From the Midea manual for the R32 M thermal Arctic Mono. Check the model on the data plate before you order parts.