Midea R32 M thermal Arctic Mono fault L4

MCE error

Heat pump

What it means

MCE error detected by refrigerant system main PCB. Displayed as P6/H4 on user interface.

Likely causes

  1. Compressor is over-current
  2. Inverter PCB has malfunctioned
  3. Inverter module damaged
  4. Motor control error
  5. Discharge temperature exceeding 105°C indicating high compressor load or high ambient/system conditions
  6. Crushed or bent pipe
  7. Blocked EXV
  8. Dirty filter
  9. Compressor current exceeding Currentmax threshold

Where to start

  1. Restart unit
  2. Use clip-on ammeter to measure compressor current
  3. Measure the resistance between each of U, V and W and each of P and N on the inverter module