Intergas HRE / Rapid / ECO RF fault 3

Ventilation

Gas boiler

What it means

When the appliance is started the fan is first brought to starting speed; once reached, the burner is lit. Code 3 is also visible during post-ventilation after the burner has stopped.

Likely causes

  1. Gas tap closed
  2. Air in gas pipe
  3. Gas supply pressure too low
  4. No ignition / worn ignition electrode
  5. No spark / faulty ignition unit on gas valve
  6. Gas/air adjustment not correctly set
  7. Fan faulty
  8. Fan dirty
  9. Gas valve faulty

Where to start

  1. Remove the cover cap (A) on the gas valve to access setting screw B.
  2. Activate the test program for minimum output by simultaneously pressing the two buttons (flame/minus icons); a capital L appears in the service display.
  3. Wait until the analyser reading is stable (minimum 3 minutes).

The full answer, free

  • 27 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 12), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Intergas manual for the HRE / Rapid / ECO RF. Check the model on the data plate before you order parts.