Intergas HRE / Rapid / ECO RF fault 2
S1 and S2 interchanged
Gas boilerWhat it means
The boiler controller has detected that sensors S1 and S2 are connected in swapped/incorrect positions.
Likely causes
- S1 or S2 sensor fault
- Burner not firing on CH due to sensor S1 or S2 fault
Where to start
- Check room thermostat / weather-dependent adjustment - check wiring, replace thermostat or weather-dependent adjustment if faulty
- If OK, check for current (24V) - check wiring against diagram, check connector X4, replace faulty manager
- If current present, check if pump is running - check power supply, check connector X2, replace faulty pump