Grant Aerona R290 fault E58
Gas sensor
Heat pumpWhat it means
Gas sensor related fault. Fault name is truncated in the source table as 'GAS SENSOR' with no further qualifier shown.
Likely causes
- Cables incorrectly connected
- Refrigerant & Drive PCB is faulty
Where to start
- Check all connections from the Refrigerant PCB (or Refrigerant & Drive PCB for the 16kW model)
The full answer, free
- How to put it right, step by step
- The manual page for this fault (page 61), right under the answer
Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.
From the Grant manual for the Aerona R290. Check the model on the data plate before you order parts.
Other Grant Aerona R290 fault codes
- 1Pump over-voltage protection
- 2Pump under-voltage protection
- 3Pump over-current protection
- 4Pump light-load protection
- 5Pump phase loss protection
- 6Pump block protection
- 7Pump over-temperature protection
- E01Connection fault between wiring centre and heat pump
- E34AC input voltage is abnormal
- E35Drive EEPROM error
- E36Power off reset
- E37Reserved
- E38Reserved
- E57Gas sensor offline
- P01Air in system or low water level