Grant Aerona R290 fault E13

Discharge pressure sensor fault

Heat pump

What it means

Discharge pressure sensor fault due to incorrect connection, sensor failure, or faulty refrigerant PCB.

Likely causes

  1. Sensor connection incorrectly connected
  2. Sensor failure
  3. The refrigerant PCB is faulty

Where to start

  1. Check correct connection of sensor
  2. Use a multimeter to check if sensor has short circuit or is faulty
  3. Check the refrigerant PCB