Connection fault between wiring centre and heat pump
Heat pumpWhat it means
Displayed on the touch screen display during initial switch on, indicating a communication or connection issue between the wiring centre and the heat pump.
Likely causes
- Faulty or loose connection between wiring centre and heat pump
- Wire disconnection or wiring error between the heat pump, wiring centre and touch screen display
- Fuse on the hydraulic module PCB may have failed
- Fuse on the Smart Controller wiring centre PCB may have failed
Where to start
- Check wiring between heat pump, wiring centre and touch screen display
- Check fuse on hydraulic module PCB
- Check fuse on Smart Controller wiring centre PCB
The full answer, free
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 52), right under the answer
Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.
From the Grant manual for the Aerona R290. Check the model on the data plate before you order parts.