Grant Aerona R290 fault E35
Drive EEPROM error
Heat pumpWhat it means
Internal diagnostic fault relating to the Drive EEPROM. This error code indicates internal diagnostics active; heat pump will not shut down.
Likely causes
- Cables incorrectly connected
- Refrigerant & Drive PCB is faulty
- Fuse is burnt out
- Connection to PCB is loose or disconnects
- Pump failure
- Too low voltage
- Pump rotors are stuck
- Wire disconnection or wiring error between the heat pump, wiring centre and touch screen display
- Fuse on the hydraulic module PCB may have failed
- Fuse on the Smart Controller wiring centre PCB may have failed
Where to start
- Check all connections from the Refrigerant PCB (or Refrigerant & Drive PCB for the 16kW model)
- Check fuse condition
- Check pump connection to Hydraulic PCB
The full answer, free
- 10 more checks in order
- How to put it right, step by step
- The manual page for this fault (page 61), right under the answer
Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.
From the Grant manual for the Aerona R290. Check the model on the data plate before you order parts.
Other Grant Aerona R290 fault codes
- 1Pump over-voltage protection
- 2Pump under-voltage protection
- 3Pump over-current protection
- 4Pump light-load protection
- 5Pump phase loss protection
- 6Pump block protection
- 7Pump over-temperature protection
- E01Connection fault between wiring centre and heat pump
- E34AC input voltage is abnormal
- E36Power off reset
- E37Reserved
- E38Reserved
- E57Gas sensor offline
- E58Gas sensor
- P01Air in system or low water level