Grant Aerona R290 fault E34
AC input voltage is abnormal
Heat pumpWhat it means
AC input voltage supplied to the unit is outside expected range.
Likely causes
- Cables incorrectly connected
- Refrigerant & Drive PCB is faulty
- Fuse is burnt out
- Connection to PCB is loose or disconnects
- Pump failure
- Too low voltage
- Pump rotors are stuck
Where to start
- Check all connections from the Refrigerant PCB (or Refrigerant & Drive PCB for the 16kW model)
- Check fuse condition
- Check pump connection to Hydraulic PCB
The full answer, free
- 12 more checks in order
- How to put it right, step by step
- The manual page for this fault (page 61), right under the answer
Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.
From the Grant manual for the Aerona R290. Check the model on the data plate before you order parts.