Grant Aerona R290 fault E30

IPM module temperature sensor failure

Heat pump

What it means

Temperature sensor for IPM module has failed.

Likely causes

  1. Cables incorrectly connected
  2. Refrigerant & Drive PCB is faulty
  3. Outdoor air temperature (T4) below 7°C combined with low return (TA) or flow (TB) water temperature below 6°C

Where to start

  1. Check all connections from the Refrigerant PCB (or Refrigerant & Drive PCB for the 16kW model)
  2. Check ambient temperature sensor (T4) reading
  3. Check inlet/outlet water temperature

The full answer, free

  • 21 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 60), right under the answer

Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.

From the Grant manual for the Aerona R290. Check the model on the data plate before you order parts.