Worcester Bosch Greenstar i System ErP fault EA229
Loss of ionisation signal during operation
Gas boilerFree account: the readings and the manual page (page 67). No card needed.See the full EA229 answer
What it means
Ignition/ionisation fault: the flame (ionisation) signal was lost while the burner was running.
Likely causes
- Incorrect gas-air ratio.
- Incorrect dynamic gas pressure.
- Faulty wiring/connection of the flame probe.
- Defective flame probe.
Where to start
- Check the gas-air ratio.
- Check the dynamic gas pressure.
- Check the wiring and connection of the flame probe.
The full answer, free
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 67), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
Full EA229 fix, readings and manual page. Free.See the full answer
From the Worcester Bosch manual for the Greenstar i System ErP. Check the model on the data plate before you order parts.
Other Worcester Bosch Greenstar i System ErP fault codes
- 9U233Internal error: control box or HCM defective or loose
- A1281Pump stuck or running dry
- B7257Internal error: control box or HCM defective
- C1264Fan stopped during operation
- C4237Internal error: control box or HCM defective
- C6215Fan speed too high
- C6216Fan speed too low
- C7214Fan does not run during start up
- C7217Fan has stopped during appliance operation
- CC800Outdoor sensor defect
- D4341Primary flow temperature rising too fast
- E2222Flow temperature sensor shorted
- E2223Flow temperature sensor disconnected
- E2350Flow temperature sensor shorted
- E2351Flow temperature sensor disconnected
- E9224Flue or high limit thermostat activated
- E9276Primary flow temperature exceeded 95 °C
- EA227No ionisation after ignition
- EA261HCM potentially defective
- EH258Internal error: control box or HCM defective
- F0238Gas valve or control box error
- F0239Internal error: control box or HCM defective
- F0258Internal error: control box or HCM defective
- F0262Internal error: control box or HCM defective