Worcester Bosch Greenstar i System ErP fault C1264

Fan stopped during operation

Gas boiler
Free account: the readings and the manual page (page 66). No card needed.See the full C1264 answer

What it means

Fan/airflow fault: the fan stopped during operation.

Likely causes

  1. Fan harness or connector fault.
  2. No mains supply to the fan.
  3. Faulty fan.

Where to start

  1. Check the fan harness and connector.
  2. Check for 230 Vac across the brown and blue wires at the fan.
  3. Check fan operation.

The full answer, free

  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 66), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

Full C1264 fix, readings and manual page. Free.See the full answer

From the Worcester Bosch manual for the Greenstar i System ErP. Check the model on the data plate before you order parts.