Worcester Bosch Greenstar i System ErP fault E2223

Flow temperature sensor disconnected

Gas boiler
Free account: the readings and the manual page (page 66). No card needed.See the full E2223 answer

What it means

Flow sensor fault: the control reads the flow temperature sensor (NTC) as disconnected. The manual lists 222 and 350 both as shorted, and 223 and 351 both as disconnected, with the same checks.

Likely causes

  1. Sensor harness or connector fault.
  2. Faulty flow temperature sensor.

Where to start

  1. Check the sensor harness and connector (flow temperature sensor NTC, item 11 on the electrical diagram, Fig. 3, page 14; on the heat exchanger, Fig. 82, page 59).
  2. Check sensor operation.

The full answer, free

  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 66), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

Full E2223 fix, readings and manual page. Free.See the full answer

From the Worcester Bosch manual for the Greenstar i System ErP. Check the model on the data plate before you order parts.