Vaillant aroTHERM fault M32
Low heating installation filling pressure warning
Heat pumpWhat it means
Message M32 appears when the filling pressure of the heating installation falls below 0.07 MPa (0.7 bar). This is a warning indication, not a lockout fault, and is accompanied by a symbol displayed after approximately one minute.
Likely causes
- Loss of heating water pressure
- Leak in heating installation
- Loss of heating water from the installation
- Leak in the heating circuit
- Insufficient initial filling pressure
- Pressure drop in heating installation
- Low filling pressure in heating installation
- Heating water leak
- Loss of system pressure
- Pressure drop in system
- Filling pressure outside permitted range causes flashing indication
- Low or high system filling pressure
- Air in system
- Pressure drop below minimum threshold
Where to start
- Use Menu → Live Monitor → Water pressure to display current filling pressure
- Monitor if pressure drops frequently to identify source of pressure loss
- Use Menu → Live Monitor Water pressure to display the filling pressure of the heating installation
The full answer, free
- 30 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 10), right under the answer
Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.
From the Vaillant manual for the aroTHERM. Check the model on the data plate before you order parts.
Other Vaillant aroTHERM fault codes
- F.073Sensor fault: building circ. water pressure
- F.094Fault: vortex
- F.103Fault: spare part ident
- F.1117Compressor: phase failure
- F.22Heating installation filling pressure critically low
- F.514Sensor fault: compr. inlet temp
- F.517Sensor fault: compr. outlet temp
- F.519Sensor fault: building circuit return temp
- F.520Sensor fault: building circuit flow temp
- F.526Sensor fault: EEV outlet temp
- F.582Fault: EEV
- F.585Sensor fault: capac. outlet temp
- F.723Building circuit: pressure too low
- F.729Compressor outlet temperature too low
- F.731High-pressure switch open
- F.732Compressor outlet temperature too high
- F.733Evaporation temperature too low
- F.734Condensation temperature too low
- F.735Evaporation temperature too high
- F.737Condensation temperature too high
- F.741Building circuit: return temp. too low
- F.752Fault: frequency converter
- F.755Fault: 4-port valve position not correct
- F.774Sensor fault: air inlet temp