Vaillant aroTHERM fault F.094

Fault: vortex

Heat pump

What it means

Volume flow (Vortex) sensor fault.

Likely causes

  1. Volume flow sensor not connected or sensor input has short-circuited
  2. Heating flow temperature below 4 °C

Where to start

  1. Check the sensor
  2. Monitor heating flow temperature
  3. Verify compressor activation when temperature drops

The full answer, free

  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 34), right under the answer

Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.

From the Vaillant manual for the aroTHERM. Check the model on the data plate before you order parts.