Vaillant aroTHERM fault LHM37
Comfort protection mode active
Heat pumpWhat it means
The product is in Comfort protection mode. The product has detected a permanent fault and continues to run with restricted comfort. The maintenance symbol is shown in the display indicating restricted operation, not full fault lockout.
Likely causes
- Permanent fault detected by the product's control system
- Permanent internal fault detected by the product
- Building power supply switched off
- Domestic hot water or heating set to off, or temperature set too low
- Air in the heating installation
- Extended pump inactivity leading to seizing/sticking
- Prolonged pump inactivity leading to seizing/sticking
- Pump inactivity leading to sticking/seizure
- Extended pump inactivity (23 hours) risking seizure
- Pump inactivity for extended period Pump stiction after extended idle period Pump inactivity for extended period
- Negative outdoor temperatures Heat pump fault Power cut Defective compressor
- System control failure
- Power cut
- Defective compressor
Where to start
- Check display for maintenance symbol
- Consult a competent person for diagnosis of the underlying permanent fault
- Consult a competent person for further diagnosis
The full answer, free
- 36 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 10), right under the answer
Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.
From the Vaillant manual for the aroTHERM. Check the model on the data plate before you order parts.
Other Vaillant aroTHERM fault codes
- F.073Sensor fault: building circ. water pressure
- F.094Fault: vortex
- F.103Fault: spare part ident
- F.1117Compressor: phase failure
- F.22Heating installation filling pressure critically low
- F.514Sensor fault: compr. inlet temp
- F.517Sensor fault: compr. outlet temp
- F.519Sensor fault: building circuit return temp
- F.520Sensor fault: building circuit flow temp
- F.526Sensor fault: EEV outlet temp
- F.582Fault: EEV
- F.585Sensor fault: capac. outlet temp
- F.723Building circuit: pressure too low
- F.729Compressor outlet temperature too low
- F.731High-pressure switch open
- F.732Compressor outlet temperature too high
- F.733Evaporation temperature too low
- F.734Condensation temperature too low
- F.735Evaporation temperature too high
- F.737Condensation temperature too high
- F.741Building circuit: return temp. too low
- F.752Fault: frequency converter
- F.755Fault: 4-port valve position not correct
- F.774Sensor fault: air inlet temp