Vaillant aroTHERM fault F.817
Freq. converter fault: compressor
Heat pumpWhat it means
Fault detected relating to the compressor or frequency converter, potentially caused by a compressor defect, frequency converter defect, or defective/loose connection cable.
Likely causes
- Defect in the compressor (e.g. short circuit)
- Defect in the frequency converter
- Connection cable to the compressor is defective or loose
- Low ambient/outdoor temperature causing heating flow temperature to drop
- Heating flow temperature of outdoor unit below 4°C
- Low outdoor ambient temperature
- Low heating flow temperature at outdoor unit
- System control failure
- Power cut
- Defective compressor
- Negative outdoor temperatures Heat pump fault Power cut Defective compressor
- Heating flow temperature below 4 °C
Where to start
- Measure the winding resistance in the compressor
- Measure the frequency converter output between the three phases
- Check the wiring harness and plug connections
The full answer, free
- 33 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 37), right under the answer
Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.
From the Vaillant manual for the aroTHERM. Check the model on the data plate before you order parts.
Other Vaillant aroTHERM fault codes
- F.073Sensor fault: building circ. water pressure
- F.094Fault: vortex
- F.103Fault: spare part ident
- F.1117Compressor: phase failure
- F.22Heating installation filling pressure critically low
- F.514Sensor fault: compr. inlet temp
- F.517Sensor fault: compr. outlet temp
- F.519Sensor fault: building circuit return temp
- F.520Sensor fault: building circuit flow temp
- F.526Sensor fault: EEV outlet temp
- F.582Fault: EEV
- F.585Sensor fault: capac. outlet temp
- F.723Building circuit: pressure too low
- F.729Compressor outlet temperature too low
- F.731High-pressure switch open
- F.732Compressor outlet temperature too high
- F.733Evaporation temperature too low
- F.734Condensation temperature too low
- F.735Evaporation temperature too high
- F.737Condensation temperature too high
- F.741Building circuit: return temp. too low
- F.752Fault: frequency converter
- F.755Fault: 4-port valve position not correct
- F.774Sensor fault: air inlet temp