Samsung EHS fault E463

OLP over heat and comp stop (current trip)

Heat pump
Free account: 2 more checks, the readings and the manual page (page 68). No card needed.See the full E463 answer

What it means

Over current trip / PFC over current error flowchart (same chart as E462) checks outdoor and indoor unit installation, obstacles, compressor operation, service valve opening before exchanging compressor or inverter PCB.

Likely causes

  1. Supply voltage not suitable
  2. Refrigerant not charged correctly
  3. Outdoor fan not working normally
  4. Obstacle around the indoor or outdoor unit
  5. Compressor not working normally
  6. Service valves not fully open
  7. Faulty inverter PCB

Where to start

  1. Check the outdoor unit is installed to the installation manual with nothing obstructing it. Remove any obstacle.
  2. Check the indoor unit the same way.
  3. Check the compressor works normally. If not, replace the compressor.

The full answer, free

  • 2 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 68), right under the answer

Safety: Isolate the heat pump and any backup heater, and give any inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.

Full E463 fix, readings and manual page. Free.See the full answer

From the Samsung manual for the EHS. Check the model on the data plate before you order parts.