Samsung EHS fault 462

All currency control COMP stop or CT2 low currency

Heat pump
Free account: 2 more checks, the readings and the manual page (page 51). No card needed.See the full 462 answer

What it means

All currency control compressor stop or CT2 low current condition detected.

Likely causes

  1. Supply voltage not suitable
  2. Refrigerant not charged correctly
  3. Outdoor fan not working normally
  4. Obstacle around the indoor or outdoor unit
  5. Compressor not working normally
  6. Service valves not fully open
  7. Faulty inverter PCB

Where to start

  1. Check the outdoor unit is installed to the installation manual with nothing obstructing it. Remove any obstacle.
  2. Check the indoor unit the same way.
  3. Check the compressor works normally. If not, replace the compressor.

The full answer, free

  • 2 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 51), right under the answer

Safety: Isolate the heat pump and any backup heater, and give any inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.

Full 462 fix, readings and manual page. Free.See the full answer

From the Samsung manual for the EHS. Check the model on the data plate before you order parts.