Samsung EHS fault 554

GasLeak error

Heat pump
Free account: 2 more checks, the readings and the manual page (page 51). No card needed.See the full 554 answer

What it means

Gas leak error detected in outdoor unit.

Likely causes

  1. Refrigerant not charged or short of charge
  2. Evaporator sensor of the indoor unit not connected correctly
  3. Service valves not fully open
  4. Compressor winding fault
  5. Faulty inverter PCB

Where to start

  1. Measure the resistance between each compressor phase (U-V, V-W, W-U): it should be smaller than 2 Ω. Higher: replace the compressor.
  2. Check the service valves are fully open.
  3. Check the indoor unit evaporator sensor is connected correctly.

The full answer, free

  • 2 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 51), right under the answer

Safety: Isolate the heat pump and any backup heater, and give any inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.

Full 554 fix, readings and manual page. Free.See the full answer

From the Samsung manual for the EHS. Check the model on the data plate before you order parts.