Samsung EHS fault E322

EVI-OUT temperature sensor fault (AE***BXYD*G models)

Heat pump
Free account: 5 more checks, the readings and the manual page (page 63). No card needed.See the full E322 answer

What it means

On AE***BXYD*G model variant, indicates a fault with the EVI-OUT temperature sensor at CN403 (WHT connector) pins 15,16 in MAIN PBA.

Likely causes

  1. Sensor open circuit
  2. Sensor short circuit
  3. Sensor connector not connected or mismatched by color
  4. Sensor wire broken or poor contact
  5. Temperature sensor fractured or damaged
  6. Resistance value out of range for sensed temperature

Where to start

  1. Power off the unit
  2. Check if the connector is connected to match the color
  3. Check if the temperature sensor is connected properly without fracture

The full answer, free

  • 5 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 63), right under the answer

Safety: Isolate the heat pump and any backup heater, and give any inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.

Full E322 fix, readings and manual page. Free.See the full answer

From the Samsung manual for the EHS. Check the model on the data plate before you order parts.

Other Samsung EHS fault codes