Samsung EHS fault E203

Time out (1min.) of communication error between MAIN PBA and INV. PBA

Heat pump
Free account: the readings and the manual page (page 62). No card needed.See the full E203 answer

What it means

A communication timeout of 1 minute occurs between the MAIN PBA and INVERTER PBA, indicating loss of communication signal between these two boards.

Likely causes

  1. Communication or power cable between the MAIN PBA and INVERTER PBA not connected properly
  2. Faulty MAIN PBA or INVERTER PBA

Where to start

  1. Check the communication and power cable between the MAIN PBA (CN305) and the INVERTER PBA (CN31) is connected properly.
  2. If the error stays, replace the MAIN PBA, then the INVERTER PBA.

The full answer, free

  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 62), right under the answer

Safety: Isolate the heat pump and any backup heater, and give any inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.

Full E203 fix, readings and manual page. Free.See the full answer

From the Samsung manual for the EHS. Check the model on the data plate before you order parts.

Other Samsung EHS fault codes