Samsung EHS fault E202

Control kit / outdoor unit communication error

Heat pump
Free account: 1 more check, the readings and the manual page (page 57). No card needed.See the full E202 answer

What it means

General communication error between control kit and outdoor unit.

Likely causes

  1. Communication cable short or open circuit
  2. No response from the hydro unit PCB
  3. Power or communication cable connected wrongly
  4. Faulty PCB (comm. kit PCB or outdoor unit PCB)

Where to start

  1. Check for a response from the hydro unit PCB: LED01 (red) should be blinking. Not blinking: check the communication cable and replace the hydro unit PCB.
  2. Check the power and communication cables are connected correctly.
  3. Remove the communication cable between the outdoor and indoor unit and measure the signal on LINE 2 of the outdoor unit with a scope: it should be a square wave over ±0.7 V. A multimeter can be used if there is no scope.

The full answer, free

  • 1 more check in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 57), right under the answer

Safety: Isolate the heat pump and any backup heater, and give any inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.

Full E202 fix, readings and manual page. Free.See the full answer

From the Samsung manual for the EHS. Check the model on the data plate before you order parts.