Samsung EHS fault E201
Control kit / outdoor unit communication error (matching error)
Heat pumpFree account: 4 more checks, the readings and the manual page (page 50). No card needed.See the full E201 answer
What it means
Communication mismatch error between control kit and outdoor unit.
Likely causes
- Faulty communication cable between outdoor unit and Hydro unit
- Faulty Hydro unit PCB
- Faulty outdoor unit PCB
- Poor signal integrity on communication line (LINE 2)
- Communication wiring fault
Where to start
- Check if there is a response from the Hydro unit PCB (LED01 (RED) is not ON); if no response (No): Check the communication cable and replace the Hydro unit PCB
- If response (Yes): Remove the communication cable connecting the outdoor unit to the Hydro unit, and measure the signal on LINE 2 of the outdoor unit with a scope
- If waveform is Good (Yes): Reconnect the cable connecting the outdoor unit to the Hydro unit and restart the unit. If communication still doesn't work, replace the Hydro unit PCB
The full answer, free
- 4 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 50), right under the answer
Safety: Isolate the heat pump and any backup heater, and give any inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.
Full E201 fix, readings and manual page. Free.See the full answer
From the Samsung manual for the EHS. Check the model on the data plate before you order parts.
Other Samsung EHS fault codes
- 108Setting address duplicate error
- 121Error of ROOM temperature sensor in indoor unit short/open
- 122Error of Evaporator_in sensor of indoor unit short/open
- 123Error of Evaporator_out sensor of indoor unit short/open
- 162Outdoor UNIT EEPROM error
- 201CONTROL KIT / outdoor UNIT communication error (matching error)
- 202CONTROL KIT / outdoor UNIT communication error
- 203Communication error between indoor / outdoor INV <-> MAIN MICOM
- 221Outdoor temperature sensor error (open/short)
- 231COND_OUT main temperature sensor error (open/short)
- 251Discharge temperature sensor error (open/short)
- 276Compressor top temperature sensor error (open/short)
- 308Suction sensor error (open/short)
- 321EVI inlet sensor error (open/short)
- 322EVI outlet sensor error (open/short)
- 458Outdoor unit fan error
- 462All currency control COMP stop or CT2 low currency
- 463OLP over heat and comp stop
- 464[inverter] DC peak error
- 466[inverter] DC-link voltage under/over error
- 467COMP revolute error
- 475Outdoor unit BLDC fan error
- 507Comp down due to high pressure or high pressure switch open
- 554GasLeak error