Rinnai Infinity fault SE
Cascade diagnostic display
ApplianceFree account: 18 more checks, the readings and the manual page (page 17). No card needed.See the full SE answer
What it means
With cascade connections, the display will flash between "SE" and the selected set temperature when an error code is displayed on any secondary unit, indicating a fault exists in the cascade system.
Likely causes
- Error code present on a secondary unit in a cascade configuration
- Pipe length
- Pipe insulation quality
- Ambient/environmental conditions
Where to start
- Check secondary units in the cascade for active error codes
- Compare control panel set temperature against measured temperature at the point of use.
- Code 01: Water Flow Data reading in units of x0.1 l/min
The full answer, free
- 18 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 17), right under the answer
Safety: Isolate whatever supplies the unit has (electric, gas, water, refrigerant) and prove dead before you open it up.
Full SE fix, readings and manual page. Free.See the full answer
From the Rinnai manual for the Infinity. Check the model on the data plate before you order parts.
Other Rinnai Infinity fault codes
- 10Air supply and combustion air duct is blocked
- 11Ignition failure
- 12Flame current abnormal
- 14Thermal fuse operates / overheat switch operates (AK/ZK only)
- 17Gas stage control valve blocked
- 19Control circuit short
- 25Drain level abnormal
- 51Inlet water thermistor faulty
- 52Main solenoid valve faulty
- 54Exhaust temp abnormal
- 55Service required / maintenance indicator
- 61Combustion fan rotation abnormal
- 71Solenoid valve & heater circuit faulty
- FFMaintenance indicator code