Rinnai Infinity fault 52
Main solenoid valve faulty
ApplianceFree account: 3 more checks, the readings and the manual page (page 51). No card needed.See the full 52 answer
What it means
Main solenoid valve fault detected.
Likely causes
- Faulty gas valve
- Main solenoid valve coil failure or wiring fault
Where to start
- Measure voltage at gas solenoid valve connector D7 Y-BK: expect 11-14V in operation
- Measure coil resistance
- Remove power plug from socket to eliminate cause
The full answer, free
- 3 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 51), right under the answer
Safety: Isolate whatever supplies the unit has (electric, gas, water, refrigerant) and prove dead before you open it up.
Full 52 fix, readings and manual page. Free.See the full answer
From the Rinnai manual for the Infinity. Check the model on the data plate before you order parts.
Other Rinnai Infinity fault codes
- 10Air supply and combustion air duct is blocked
- 11Ignition failure
- 12Flame current abnormal
- 14Thermal fuse operates / overheat switch operates (AK/ZK only)
- 17Gas stage control valve blocked
- 19Control circuit short
- 25Drain level abnormal
- 51Inlet water thermistor faulty
- 54Exhaust temp abnormal
- 55Service required / maintenance indicator
- 61Combustion fan rotation abnormal
- 71Solenoid valve & heater circuit faulty
- FFMaintenance indicator code
- SECascade diagnostic display