What it means
A diagnostic code '55' indicates the unit requires servicing. As part of the service it is recommended that a flush be carried out to avoid any damage to the heat exchanger, especially in hard water areas. Failure to flush the appliance will cause damage to the heat exchanger from lime build-up.
Likely causes
- Programmed service interval time period has elapsed
- Water conditions or other factors affecting heat exchanger condition
- Scheduled maintenance interval reached
- Lime/scale build-up risk in hard water areas
- Scheduled service interval reached
Where to start
- Check controller display for '55' code
- Flush the heat exchanger per paragraph 3.8.2
- Refer to flushing instructions in the manual
The full answer, free
- 3 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 53), right under the answer
Safety: Isolate whatever supplies the unit has (electric, gas, water, refrigerant) and prove dead before you open it up.
Full 55 fix, readings and manual page. Free.See the full answer
From the Rinnai manual for the Infinity. Check the model on the data plate before you order parts.
Other Rinnai Infinity fault codes
- 10Air supply and combustion air duct is blocked
- 11Ignition failure
- 12Flame current abnormal
- 14Thermal fuse operates / overheat switch operates (AK/ZK only)
- 17Gas stage control valve blocked
- 19Control circuit short
- 25Drain level abnormal
- 51Inlet water thermistor faulty
- 52Main solenoid valve faulty
- 54Exhaust temp abnormal
- 61Combustion fan rotation abnormal
- 71Solenoid valve & heater circuit faulty
- FFMaintenance indicator code
- SECascade diagnostic display