Rinnai Infinity fault 25
Drain level abnormal
ApplianceFree account: 8 more checks, the readings and the manual page (page 49). No card needed.See the full 25 answer
What it means
Drain level abnormal, condensate drainage issue detected.
Likely causes
- Condensate pump failure
- Condensate reservoir filled with water, activating float switch
- Condensate pump unplugged or disconnected from power
- Blockage in condensate trap
- Blockage in drain line
- Condensate drain blockage
- Drain level sensor fault
Where to start
- Disconnect power from the water heater
- Open the water heater cover and locate 2 white wires labelled 'condensate pump safety switch' on the PCB
- Cut crimp connectors off white wires and strip the insulation off the two ends
The full answer, free
- 8 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 49), right under the answer
Safety: Isolate whatever supplies the unit has (electric, gas, water, refrigerant) and prove dead before you open it up.
Full 25 fix, readings and manual page. Free.See the full answer
From the Rinnai manual for the Infinity. Check the model on the data plate before you order parts.
Other Rinnai Infinity fault codes
- 10Air supply and combustion air duct is blocked
- 11Ignition failure
- 12Flame current abnormal
- 14Thermal fuse operates / overheat switch operates (AK/ZK only)
- 17Gas stage control valve blocked
- 19Control circuit short
- 51Inlet water thermistor faulty
- 52Main solenoid valve faulty
- 54Exhaust temp abnormal
- 55Service required / maintenance indicator
- 61Combustion fan rotation abnormal
- 71Solenoid valve & heater circuit faulty
- FFMaintenance indicator code
- SECascade diagnostic display