Ideal Logic fault L1
Flow temperature overheat lockout
Gas boilerWhat it means
Boiler has shut down due to flow temperature exceeding safe limits
Likely causes
- System not filled with water
- Isolation or radiator valves closed
- Pump not rotating freely
- Flow/Return differential exceeds 30°C
- Flow thermistor fault
Where to start
- Verify boiler and CH system filled with water
- Confirm all isolation and radiator valves open
- Check pump rotation freely
The full answer, free
- 2 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 49), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.