Ideal Logic fault C2

BCC fault (boiler chip card)

Gas boiler

What it means

Boiler Chip Card is not correct for this boiler or is faulty

Likely causes

  1. Incorrect BCC fitted for boiler range/output
  2. BCC not securely inserted
  3. BCC faulty

Where to start

  1. Verify correct BCC for boiler is fitted (check label on BCC)
  2. Check BCC is securely inserted into PCB slot
  3. Replace BCC with new correct BCC and reset boiler

The full answer, free

  • How to put it right, step by step
  • The manual page for this fault (page 53), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Ideal manual for the Logic. Check the model on the data plate before you order parts.

Other Ideal Logic fault codes