Ideal Logic Heat fault L2

Ignition lockout

Gas boiler
Free account: 5 more checks, the readings and the manual page (page 51). No card needed.See the full L2 answer

What it means

The boiler has failed to light, or lit briefly and gone out, and has locked out. It needs a manual reset.

Likely causes

  1. Gas pressure below 18 mbar at the boiler inlet.
  2. Detection electrode fault or contamination.
  3. Condensate pipe blocked.
  4. Flue installed incorrectly.
  5. Spark generator fault.
  6. Ignition electrode fault.
  7. Gas valve fault.
  8. Pump not wired to the boiler.

Where to start

  1. Check the gas pressure at the boiler inlet test point: minimum 18 mbar.
  2. Check the detection electrode for continuity, condition and position.
  3. Check the condensate pipe for a blockage.

The full answer, free

  • 5 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 51), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

Full L2 fix, readings and manual page. Free.See the full answer

From the Ideal manual for the Logic Heat. Check the model on the data plate before you order parts.