Ideal Logic Heat fault F5
Return thermistor fault
Gas boilerFree account: the readings and the manual page (page 52). No card needed.See the full F5 answer
What it means
Return temperature sensor reading is out of range or disconnected
Likely causes
- Return thermistor resistance out of specification
- Return thermistor wiring disconnected
- Return thermistor wiring lacks continuity to PCB
- PCB fault
Where to start
- Remove return thermistor from CH return pipe
- Disconnect thermistor wires
- Measure resistance across thermistor terminal pins using multimeter
The full answer, free
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 52), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
Full F5 fix, readings and manual page. Free.See the full answer
From the Ideal manual for the Logic Heat. Check the model on the data plate before you order parts.