Ideal Logic Heat fault F3
Fan fault
Gas boilerFree account: the readings and the manual page (page 52). No card needed.See the full F3 answer
What it means
The fan is not running or the boiler has found a fault in the fan circuit.
Likely causes
- Fan wiring loose or deteriorated.
- Fan wiring has lost continuity.
- No 230Vac supply to the fan.
- PCB fault.
Where to start
- Check the fan wiring connections are secure at both ends.
- Check the fan wiring for continuity.
- Check for 230Vac across the blue and brown connections at the 3-way fan connector.
The full answer, free
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 52), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.