Ideal Logic Heat fault FD

No water flow

Gas boiler
Free account: the readings and the manual page (page 53). No card needed.See the full FD answer

What it means

Water flow sensor detects no circulation in heating system

Likely causes

  1. Pump not rotating
  2. Pump electrical connection fault
  3. Water flow sensor connector loose
  4. Water flow sensor fault

Where to start

  1. Turn power off and on, check if pump rotates
  2. Check pump electrical connection
  3. Check water flow sensor connector security

The full answer, free

  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 53), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

Full FD fix, readings and manual page. Free.See the full answer

From the Ideal manual for the Logic Heat. Check the model on the data plate before you order parts.