Glow-worm Energy System fault S.42

Flue non-return flap closed

Gas boiler

What it means

Status indicates the flue non-return flap is in the closed position.

Likely causes

  1. Flue non-return flap stuck or closed
  2. Incorrectly installed flue without sufficient fall can cause condensate to pool, leading to flue blockage or boiler faults
  3. Leak in the flue system
  4. Flue gas recirculation in extended flue gas installations

Where to start

  1. Check flue non-return flap operation
  2. Measure CO (ppm) and CO2 (%) at max rate and calculate CO/CO2 ratio
  3. Measure CO (ppm) and CO2 (%) at min rate and calculate CO/CO2 ratio

The full answer, free

  • 12 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 50), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Glow-worm manual for the Energy System. Check the model on the data plate before you order parts.