Glow-worm Energy System fault F.01

Return temperature sensor fault

Gas boiler

What it means

Return temperature sensor fault, indicating a wiring or sensor issue preventing correct return temperature reading.

Likely causes

  1. NTC plug not plugged in or has come loose
  2. Multiple plug on the PCB not plugged in correctly
  3. Interruption in cable harness
  4. NTC sensor defective

Where to start

  1. Check NTC sensor plug connection
  2. Check multiple plug connection on PCB
  3. Check cable harness for interruption

The full answer, free

  • 1 more check in order
  • How to put it right, step by step
  • The manual page for this fault (page 50), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Glow-worm manual for the Energy System. Check the model on the data plate before you order parts.