Glow-worm Energy System fault F.22

Safety shutdown: water deficiency in the boiler

Gas boiler

What it means

Safety shutdown due to insufficient water detected in the boiler

Likely causes

  1. Water pressure in heating installation dropped below 0.03 MPa (0.3 bar)
  2. Insufficient filling or leak in heating system
  3. No or insufficient water in the product
  4. Water pressure sensor defective
  5. Cable to the pump or to the water pressure sensor loose/not connected/defective

Where to start

  1. Check displayed pressure value
  2. Confirm pressure has fallen below 0.03 MPa (0.3 bar)
  3. Check fault list for F22

The full answer, free

  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 51), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Glow-worm manual for the Energy System. Check the model on the data plate before you order parts.