Baxi Quinta Ace fault H.03.02

Flame loss detected

Appliance

What it means

Measured ionisation current is below limit - no flame during operation

Likely causes

  1. No ionisation current
  2. Air in gas supply
  3. Gas valve not fully open
  4. Gas supply pressure issue
  5. Gas valve unit setting/operation fault
  6. Blocked air supply inlet or flue gas outlet
  7. Flue gas recirculation

Where to start

  1. Vent the gas supply to remove air
  2. Check that the gas valve is fully opened
  3. Check the gas supply pressure

The full answer, free

  • 3 more checks in order
  • How to put it right, step by step
  • The manual page for this fault (page 78), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Baxi manual for the Quinta Ace. Check the model on the data plate before you order parts.